{"id":1744,"date":"2022-06-21T08:04:00","date_gmt":"2022-06-21T08:04:00","guid":{"rendered":"https:\/\/saturnoptical.com\/?post_type=product&#038;p=1744"},"modified":"2025-05-19T04:33:17","modified_gmt":"2025-05-19T04:33:17","slug":"optopol-revo-fc","status":"publish","type":"product","link":"https:\/\/saturnoptical.com\/de\/product\/optopol-revo-fc\/","title":{"rendered":"Optopol Revo FC OCT Funduskamera"},"content":{"rendered":"<p style=\"text-align: justify;\">Optopol Revo FC offers all the proven advantages of REVO systems with state-of-the-art color imaging for a new level of diagnostic certainty. High-quality OCT scanning and comprehensive analysis of the retinal layers combined with fundus imaging make the examination more versatile than ever.<\/p>\n<p style=\"text-align: justify;\">Optopol Revo FC is an OCT combined with a Fundus Camera. It is a versatile tool that combines high-resolution OCT images with true-color background images. Acquisitions are fully automatic for Retina, Optical Disc, and Anterior Segment.<\/p>\n<p style=\"text-align: justify;\">The tool can be implemented with the Angiography module (optional) and with the Biometry module (optional).\u00a0Like all Optopol OCT models, REVO FC interfaces with Optopol Perimeters for a simultaneous structural and functional damage analysis.<\/p>\n<p style=\"text-align: justify;\">\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<\/p>\n<div class=\"embed-container\" style=\"text-align: justify;\"><iframe src=\"https:\/\/www.youtube.com\/embed\/ZQiEob1-_d0\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<h2 style=\"text-align: justify;\">Optopol Revo FC Key Features:<\/h2>\n<ul style=\"text-align: justify;\">\n<li>80,000 scans\/second<\/li>\n<li>True Color NonMyd.\u00a0Integrated fundus camera<\/li>\n<li>OCT-A: OCT angiography<\/li>\n<li>B-OCT: Biometrics module<\/li>\n<li>Anterior Wide Field Adapter<\/li>\n<li>Very compact, fits in every room<\/li>\n<li>Retina &#8211; fundus camera &#8211; glaucoma &#8211; anterior segment<\/li>\n<li>Fully automatic one-touch measurement<\/li>\n<li>Fully equipped, good price<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">Optopol Revo FC offers all the proven benefits of REVO systems with state-of-the-art Fundus imaging technology for a new diagnostic confidence level. High-quality OCT scanning and comprehensive retinal layer analysis combined with Fundus imaging make examination versatile like never before.<\/p>\n<p style=\"text-align: justify;\">What makes the REVO FC truly unique is the integrated non-mydriatic 12.3 Mpix Fundus camera, which can capture extremely high-quality and detailed color images. The REVO FC Fundus Camera is fully automated, safe, and easy to use.<\/p>\n<p style=\"text-align: justify;\">Optopol Revo FC, with a scanning speed of 80,000 A-scans \/ sec, offers advanced technologies and remarkable simplicity of operation. It meets all requirements for modern optical tomography.<\/p>\n<h2 style=\"text-align: justify;\">The Copernicus REVO FC offers:<\/h2>\n<h3 style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-1753\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/3D-retina.png\" alt=\"\" width=\"85\" height=\"85\" \/>3D retina<\/h3>\n<ul style=\"text-align: justify;\">\n<li>Up to 12 X 12 mm scan area<\/li>\n<li>8 layers are recognized automatically<\/li>\n<li>Automatic follow-up<\/li>\n<li>Normative Databases for Retinal Thickness and Ganglion Complex<\/li>\n<li>Progress display of max. 6 examinations<\/li>\n<li>Comparison of any two studies<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-1755\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/fundus-camera.png\" alt=\"\" width=\"85\" height=\"85\" \/>fundus camera<\/h3>\n<ul style=\"text-align: justify;\">\n<li>True color fundus camera<\/li>\n<li>45\u00b0 Non-Mydriatic<\/li>\n<li>12 megapixel CCD camera<\/li>\n<li>Fully automatic photography<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\"><img decoding=\"async\" class=\"alignnone size-full wp-image-1760\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Real-time-hardware-eye-tracking.png\" alt=\"\" width=\"200\" height=\"193\" \/>Real time hardware eye tracking<\/h3>\n<ul style=\"text-align: justify;\">\n<li>Active tracking in real time<\/li>\n<li>Perfect help with eye movement and blinking<\/li>\n<li>Accurate OCT images<\/li>\n<li>For precise follow-up examinations<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1757\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/glaucoma.png\" alt=\"\" width=\"85\" height=\"85\" \/>glaucoma<\/h3>\n<ul style=\"text-align: justify;\">\n<li>Geometrical evaluation of the optic nerve (cup\/disc)<\/li>\n<li>Nerve Fiber Layer Analysis (GDX)<\/li>\n<li>DDLS analysis<\/li>\n<li>Ganglion Complex Analysis<\/li>\n<li>Automatic follow up<\/li>\n<li>Normative databases for geometries (cup\/disc), nerve fibers, ganglion cells<\/li>\n<li>Progress display of up to 6 examinations<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1756\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/ganglion-cell-analysis.png\" alt=\"\" width=\"85\" height=\"85\" \/>ganglion cell analysis<\/h3>\n<p style=\"text-align: justify;\">The REVO OCT&#8217;s ganglion cell analysis provides an additional glaucoma analysis to the conventional papillary retinal nerve fiber layer thickness measurement. You can choose between three analysis forms: NFL+GCL+ IPL Thickness, GCL+ IPL Thickness, and NFL Thickness, which are additionally supported by respective NDBs.<\/p>\n<p style=\"text-align: justify;\">Combining ganglion cell analysis with papillary retinal nerve fiber layer thickness provides a better biomarker for managing glaucoma.<\/p>\n<h3 style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1754\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Anterior-wide-field.png\" alt=\"\" width=\"85\" height=\"70\" \/>Anterior wide field<\/h3>\n<ul style=\"text-align: justify;\">\n<li>Integrated front section module (5 x 5 mm)<\/li>\n<li>Automatic pachymetry<\/li>\n<li>Analysis of the chamber angle<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong>Optional wide-angle module (14 x 5 mm):<\/strong><\/p>\n<ul style=\"text-align: justify;\">\n<li>Representation of the complete front system<\/li>\n<li>Measurement of two chamber angles in one exposure<\/li>\n<li>representation of the iris<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1758\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/OCT-biometrics.png\" alt=\"\" width=\"85\" height=\"85\" \/>OCT biometrics<\/h3>\n<p style=\"text-align: justify;\"><strong>Fully automatic 10-fold measurement:<\/strong><\/p>\n<ul style=\"text-align: justify;\">\n<li>AL: axis length<\/li>\n<li>ACD: anterior chamber depth<\/li>\n<li>LT: lens thickness<\/li>\n<li>CCT: corneal thickness<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">In addition, there is a scan program that displays the anterior chamber in detail. The module description provides further information on the REVO Angio Module.<\/p>\n<h3 style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1759\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/OCT-topography.png\" alt=\"\" width=\"85\" height=\"70\" \/>OCT topography<\/h3>\n<p style=\"text-align: justify;\">The OCT Topography (OCT-T) module enables a comprehensive analysis of the cornea&#8217;s two interfaces. The most important analyses include determining the cornea&#8217;s radii of curvature (K1 and K2) and the resulting refractive power.<\/p>\n<p style=\"text-align: justify;\">The values \u200b\u200bcomplete the OCT Biometrics Module (OCT-B) of the Copernicus REVO series released in version 8.0. A large number of different representations are available to evaluate the results. The OCT-T technology is based on the principle of ray tracing. In addition to the front and back surface of the cornea, the corresponding corneal thickness is also determined.<\/p>\n<h3 style=\"text-align: justify;\">Connectivity \/ Network<\/h3>\n<ul style=\"text-align: justify;\">\n<li>Free server and viewer programs (optional installation service)<\/li>\n<li>Viewers may be redistributed to affiliated stores\/locations<\/li>\n<li>site networking<\/li>\n<li>Various interfaces to your management software<\/li>\n<li>DICOM<\/li>\n<li>Automatic export<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\">Optopol Revo FC Technical specifications:<\/h3>\n<ul style=\"text-align: justify;\">\n<li><strong>Technology:<\/strong>\u00a0spectral domain OCT<\/li>\n<li><strong>Measurement modes<\/strong>\u00a0: B-scan, radial scan, grid, cross, 3D, grid scan, multiline scan, vessel scan Measurement<\/li>\n<li><strong>method:<\/strong>\u00a0fully automatic<\/li>\n<li><strong>Fundus display:<\/strong>\u00a0pSLO (live fundus reconstruction)<\/li>\n<li><strong>Fixation:<\/strong>\u00a0OLED screen (fovea and disk) \u2013 variable position and shape, external fixation<\/li>\n<li><strong>Wavelength:<\/strong>\u00a0840nm<\/li>\n<li><strong>Axial resolution:<\/strong>\u00a05 micron<\/li>\n<li><strong>horiz.\u00a0Resolution:<\/strong>\u00a012-18 microns<\/li>\n<li><strong>Axial scan depth:<\/strong>\u00a0min. 2mm<\/li>\n<li><strong>Speed:<\/strong>\u00a080,000 ascans\/s<\/li>\n<li><strong>Bscan width:<\/strong>\u00a0up to 12mm<\/li>\n<li><strong>Max. area 3D scan:<\/strong>\u00a012 X 12mm<\/li>\n<li><strong>max. A-scan \/ B-scan:<\/strong>\u00a010,500<\/li>\n<li><strong>Min. pupil:<\/strong> 2mm Device dimensions <strong>:<\/strong>\u00a047.9 x 49.3 x 36.7 (WxHxD)<\/li>\n<li><strong>Dimensions with table (STM-2):<\/strong>\u00a088 x 129-154 x 53cm (WxHxD)<\/li>\n<\/ul>\n<h4 style=\"text-align: justify;\">analysis software<\/h4>\n<ul style=\"text-align: justify;\">\n<li><strong>Retina Analysis:<br \/>\n<\/strong>Retina Thickness<br \/>\nRNFL+ GCL+IPL Thickness (Nervear Fiber Layer, Ganglion Cell Layer, Inner Plexiform Layer Thickness)<br \/>\nGCL+IPL Thickness<br \/>\nRNFL Thickness<br \/>\nRPE Deformation Map<br \/>\nIS\/OS Thickness<br \/>\nFollow Up<\/li>\n<li><strong>Glaucoma:<br \/>\n<\/strong>Nerve Fiber Layer Thickness<br \/>\nONH Morphology<br \/>\nDDLS \u2013 Disc Damage Likelyhood Scale Ganglion Cell Analysis<br \/>\nwith Asymmetry Comparison<br \/>\nFollow Up<\/li>\n<li><strong>Anterior:<br \/>\n<\/strong>Pachymetry<br \/>\nLASIK flap measurement<br \/>\nChamber angle measurement<br \/>\nWide-angle scans (with optional wide-angle module)<\/li>\n<\/ul>\n<h2 style=\"text-align: justify;\">Include:<\/h2>\n<ul style=\"text-align: justify;\">\n<li style=\"text-align: justify;\">Copernicus REVO NX FC OCT<\/li>\n<li style=\"text-align: justify;\">Anterior Module Standard (5mm)<\/li>\n<li style=\"text-align: justify;\">Viewer and Server applications<\/li>\n<li style=\"text-align: justify;\">HP All-In-One professional PC with 24\u2033 multi-touch display table package (equipment table, PC\/monitor holder, medical isolating transformer)<\/li>\n<li style=\"text-align: justify;\">OCT-A: OCT angiography plus<\/li>\n<li style=\"text-align: justify;\">T-OCT: topography module<\/li>\n<li style=\"text-align: justify;\">B-OCT: biometry Module<\/li>\n<li style=\"text-align: justify;\">anterior wide-field adapter<\/li>\n<\/ul>\n<div class=\"flex-1 overflow-hidden\">\n<div class=\"h-full\">\n<div class=\"react-scroll-to-bottom--css-enfdd-79elbk h-full\">\n<div class=\"react-scroll-to-bottom--css-enfdd-1n7m0yu\">\n<div class=\"flex flex-col text-sm md:pb-9\">\n<div class=\"w-full text-token-text-primary\" dir=\"auto\" data-testid=\"conversation-turn-29\" data-scroll-anchor=\"true\">\n<div class=\"py-2 juice:py-[18px] px-3 text-base md:px-4 m-auto md:px-5 lg:px-1 xl:px-5\">\n<div class=\"mx-auto flex flex-1 gap-3 text-base juice:gap-4 juice:md:gap-5 juice:lg:gap-6 md:max-w-3xl lg:max-w-[40rem] xl:max-w-[48rem]\">\n<div class=\"group\/conversation-turn relative flex w-full min-w-0 flex-col agent-turn\">\n<div class=\"flex-col gap-1 md:gap-3\">\n<div class=\"flex flex-grow flex-col max-w-full\">\n<div class=\"min-h-[20px] text-message flex flex-col items-start whitespace-pre-wrap break-words [.text-message+&amp;]:mt-5 juice:w-full juice:items-end overflow-x-auto gap-2\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"0b26a185-dc79-4c62-a08f-8193d6a97f2d\">\n<div class=\"flex w-full flex-col gap-1 juice:empty:hidden juice:first:pt-[3px]\">\n<div class=\"markdown prose w-full break-words dark:prose-invert dark\">\n<h3>What Makes Optopol Revo FC OCT Different from Other OCT Devices?<\/h3>\n<p>The Optopol Revo FC OCT distinguishes itself from other <a href=\"https:\/\/saturnoptical.com\/oct-device\/\"><em><strong>OCT devices<\/strong><\/em><\/a> through its advanced features, comprehensive imaging capabilities, and user-centric design. Here are the key differentiators that set the Optopol Revo FC OCT apart:<\/p>\n<h4>1. <strong>Integrated Fundus Camera and OCT<\/strong><\/h4>\n<p>The Optopol Revo FC combines OCT with a fully integrated fundus camera, enabling simultaneous acquisition of high-resolution OCT images and color fundus photographs. This dual function provides a more comprehensive assessment of retinal health, offering detailed cross-sectional and surface imaging.<\/p>\n<h4>2. <strong>High-Speed and High-Resolution Imaging<\/strong><\/h4>\n<p>The Revo FC OCT operates at a high scanning speed of 110,000 A-scans per second, significantly faster than many other OCT devices. This high speed, combined with high-resolution imaging, reduces motion artifacts and enhances image clarity, making detecting and monitoring retinal abnormalities easier.<\/p>\n<h4>3. <strong>Widefield Imaging Capability<\/strong><\/h4>\n<p>The device supports widefield imaging up to 12 mm x 9 mm, allowing for extensive retina views. This broad field of view is handy for identifying peripheral retinal pathologies and providing a more comprehensive evaluation of the retina and choroid.<\/p>\n<h4>4. <strong>Anterior Segment Imaging<\/strong><\/h4>\n<p>In addition to retinal imaging, the Optopol Revo FC OCT includes capabilities for anterior segment imaging. This feature allows for detailed examination of the cornea, iris, and other anterior segment structures, adding versatility to its diagnostic applications.<\/p>\n<h4>5. <strong>3D and Enface Imaging<\/strong><\/h4>\n<p>The Revo FC provides 3D imaging and enface views, enabling clinicians to examine the retina in various planes and perspectives. These imaging techniques facilitate a more thorough analysis of retinal conditions and improve the ability to track disease progression over time.<\/p>\n<h4>6. <strong>Automated Layer Segmentation and Advanced Analysis<\/strong><\/h4>\n<p>The device features sophisticated automated layer segmentation algorithms that accurately identify and measure individual retinal layers. These advanced analysis tools are crucial for diagnosing and monitoring diseases such as glaucoma, diabetic retinopathy, and macular degeneration with high precision.<\/p>\n<h4>7. <strong>User-Friendly Interface and Workflow Optimization<\/strong><\/h4>\n<p>The Optopol Revo FC is designed with a user-friendly interface that simplifies operation. It includes automated features for image capture, analysis, and reporting, which streamline the imaging process and enhance clinical efficiency. The intuitive design reduces the learning curve and improves workflow in busy clinical settings.<\/p>\n<h4>8. <strong>Comprehensive Data Management and Connectivity<\/strong><\/h4>\n<p>The device integrates seamlessly with electronic medical records (EMR) systems and other data management platforms, ensuring that patient data is easily accessible and well-organized. This connectivity supports efficient data management and enhances the overall quality of patient care.<\/p>\n<h4>9. <strong>Compact and Space-Saving Design<\/strong><\/h4>\n<p>The Revo FC OCT is designed to be compact and space-saving, making it suitable for clinics with limited space. Despite its small footprint, it does not compromise on imaging capabilities or performance, providing high-quality diagnostic information in a versatile and convenient package.<\/p>\n<h4>10. <strong>Proven Reliability and Support<\/strong><\/h4>\n<p>Optopol is known for its commitment to innovation and quality in ophthalmic imaging. The Revo FC OCT benefits from Optopol\u2019s extensive experience and reputation, offering clinicians reliable performance and comprehensive support services.<\/p>\n<p>Combining these advanced features and capabilities, the Optopol Revo FC OCT provides superior diagnostic performance, versatility, and user-friendliness. It is an excellent choice for eye care professionals looking to enhance their diagnostic capabilities and deliver high-quality patient care.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2 style=\"text-align: justify;\">Reference Library<\/h2>\n<ul>\n<li style=\"text-align: justify;\"><a href=\"https:\/\/www.optopol.com\/products\/REVO+FC+with+Real+Time+hardware+Eye-Tracking+\" target=\"_blank\" rel=\"noopener nofollow\">Manufacturer Information<\/a><\/li>\n<li style=\"text-align: justify;\"><a href=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/revo-fc-brochure-saturn-optical.pdf\">Brochure<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\">Optopol Revo FC offers High-quality OCT scanning and comprehensive analysis of the retinal layers combined with fundus imaging making the examination more versatile than ever.<\/p>","protected":false},"featured_media":1762,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[205],"product_tag":[241],"class_list":["post-1744","product","type-product","status-publish","has-post-thumbnail","product_cat-octs","product_tag-optopol-revo-fc","pa_brand-optopol","first","instock","sale","shipping-taxable","purchasable","product-type-simple","rey-swatches",""],"acf":[],"_links":{"self":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product\/1744","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/comments?post=1744"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/media\/1762"}],"wp:attachment":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/media?parent=1744"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product_cat?post=1744"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product_tag?post=1744"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}