{"id":1912,"date":"2022-08-05T07:45:23","date_gmt":"2022-08-05T07:45:23","guid":{"rendered":"https:\/\/saturnoptical.com\/?post_type=product&#038;p=1912"},"modified":"2024-01-10T10:22:59","modified_gmt":"2024-01-10T10:22:59","slug":"oculus-myopia-master","status":"publish","type":"product","link":"https:\/\/saturnoptical.com\/de\/product\/oculus-myopia-master\/","title":{"rendered":"OCULUS Myopia Master"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>Oculus Myopia Master<\/strong>\u00a0is the first all-in-one instrument that performs and combines the necessary measurements for the measurement and follow-up of myopia\/myopia. Myopia Master is the first instrument in the world that combines the essential things in 1 device. The built-in autorefractor obtains the objective refraction.<\/p>\n<blockquote><p>\u201cThis license agreement is another example of the cutting-edge technology emerging at BHVI.\u00a0In 2016, BHVI literally &#8220;wrote the book&#8221; on myopia\u00a0with the publication of the landmark research report Global Prevalence\u00a0of\u00a0<em>Myopia and High Myopia and Temporal Trends from 2000 through 2050\u00a0<\/em><em>.\u00a0<\/em>Through our agreement with OCULUS, our research will result in additional tools that optometrists around the world can use to care for people with myopia.\u201d<\/p>\n<p><strong>CEO of BHVI, Yvette Waddell.<\/strong><\/p><\/blockquote>\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<div class=\"embed-container\"><iframe src=\"https:\/\/www.youtube.com\/embed\/wP_JZgkqNZ0\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\">Also, the shaft length and the central keratometer values \u200b\u200bare measured. These measurements are carried out fully automatically and according to the non-contact method. So especially children can be counted quickly and comfortably. Anesthesia is superfluous by this method.<\/p>\n<p style=\"text-align: justify;\">OCULUS Myopia Master records all the essential parameters for the care of people affected by myopia: axial length, refraction values, \u200b\u200band the central corneal radii. Leading experts now consider the axial length measurement the gold standard for determining intolerance and is part of the tools of the trade for every myopia expert. This fast, non-contact, and high-precision measuring method is not influenced by accommodation and provides reproducible results for children.<\/p>\n<div class=\"drag_block tab\" style=\"text-align: justify;\">\n<div class=\"tabs grey\">\n<div class=\"tab-content\">\n<div id=\"desc\" class=\"tab-pane active\">\n<h2 class=\"content\"><b>OCULUS Myopia Master Benefits<\/b><\/h2>\n<ul>\n<li>\n<h3>Myopia Management Redefined<\/h3>\n<\/li>\n<\/ul>\n<p>It is being able to detect myopia at an early stage is critical. In cooperation with the Brien Holden Vision Institute, the values measured are compared with age-related normative data derived from a database of about 25 000 eyes. The growth curve makes it possible to compare the individual measurement with normative data. The earlier an abnormality trend is recognized, the more efficiently it can be counteracted with appropriate treatments.<\/p>\n<p>The diagram shows the axial length and refraction (spherical equivalents) of an individual patient\u2019s measurement in an easy-to-understand way. The growth curves support the data interpretation.<\/p>\n<p>Vital for your educational sessions: Influencing factors that can stimulate myopia development are documented in the software. A traffic light scale is provided to help visualize critical values.<\/p>\n<ul>\n<li>\n<h3>Evaluation-Based<\/h3>\n<\/li>\n<\/ul>\n<p>Categorized action recommendations provide a basis for multiple treatment options. The first steps toward success may be achieved through medication or special contact lenses.<\/p>\n<p>Special spectacle lenses and further behavioral recommendations can also be selected.<\/p>\n<p>The following routine appointment can be sent to your customer by email based on the action recommendations.<\/p>\n<ul>\n<li>\n<h3>A Report That Leaves no Questions Open<\/h3>\n<\/li>\n<\/ul>\n<p>The customer receives a comprehensive, readily understandable report explaining the status quo. In addition to the customer data and measurement results, it intuitively presents the selected action recommendations and progression diagrams.<\/p>\n<p>Along with the customer information and evaluated influencing factors, this does excellent reading for refreshing the customer\u2019s memory.<\/p>\n<ul>\n<li>\n<h3>Follow-Up Examinations and Trend Analysis \u2013 Treatment strategy and success made it easy to visualize<\/h3>\n<\/li>\n<\/ul>\n<p>One or multiple treatment strategies can be selected with a simple click. The effects of axial length growth on refraction with or without the treatment chosen method can be intuitively illustrated in a diagram. Color-coded representations explain the success of treatment to both parents and children.<\/p>\n<p>This provides the customer with an optimal overview of the individual development and a summary of the treatment strategy.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p style=\"text-align: justify;\"><strong>OCULUS Myopia Master<\/strong> combines the most important measurement parameters with other risk factors (ethnicity, myopia in parents, time spent on close work, and outdoor activities) in a specially designed software that makes the detection, treatment, and follow-up of intolerance much easier and more reliable than ever.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-1916 size-large\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master-1024x765.png\" alt=\"myopia master\" width=\"1024\" height=\"765\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master-1024x765.png 1024w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master-300x224.png 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master-768x574.png 768w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master-1536x1148.png 1536w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master-800x598.png 800w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia-master.png 2000w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h3 style=\"text-align: justify;\"><strong>The best combination: Refraction, Axis Length, and Keratometry:<\/strong><\/h3>\n<h4 style=\"text-align: justify;\"><strong>Refraction:<br \/>\n<\/strong><\/h4>\n<p style=\"text-align: justify;\">The standard method for measuring myopia is refraction. Varying from day to day, measurement results of refraction and the need to be able to measure cycloplegic refraction in children require additional measurements to follow up on myopia.<strong><br \/>\n<\/strong><\/p>\n<h4 style=\"text-align: justify;\"><strong>Axle length:<br \/>\n<\/strong><\/h4>\n<p style=\"text-align: justify;\">This can be measured accurately and independently of accommodation.\u00a0Progression in axial length is a reliable indicator of progression in myopia.\u00a0Measurement of axial length is the gold standard for myopia follow-up.<\/p>\n<h4 style=\"text-align: justify;\"><strong>Keratometry:<br \/>\n<\/strong><\/h4>\n<p style=\"text-align: justify;\">Measurement of the radii of curvature of the central part of the cornea, the primary refractive component of the eye.<\/p>\n<h3>OCULUS Myopia Master Technical Data<\/h3>\n<p>Axiall\u00e4nge<\/p>\n<table class=\"contenttable contenttable-0 technischeDaten\">\n<caption>\u00a0<\/caption>\n<tbody>\n<tr class=\"tr-even tr-0\">\n<td class=\"td-0\">Measuring range<\/td>\n<td class=\"td-1\">14 &#8211; 40 mm<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Autorefractor<\/p>\n<table class=\"contenttable contenttable-0 technischeDaten\">\n<caption>\u00a0<\/caption>\n<tbody>\n<tr class=\"tr-even tr-0\">\n<td class=\"td-0\">Corneal vertex distance (CVD)<\/td>\n<td class=\"td-1\">0; 10.5; 12; 13.75; 15; 16.5 mm<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-odd tr-1\">\n<td class=\"td-0\">Sphere<\/td>\n<td class=\"td-1\">-20 &#8211; +22 D (CVD = 12 mm)<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-even tr-2\">\n<td class=\"td-0\">Cylinder<\/td>\n<td class=\"td-1\">10 D (CDV = 12 mm)<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-odd tr-3\">\n<td class=\"td-0\">Achse<\/td>\n<td class=\"td-1\">0\u00b0 to 180\u00b0 (in 1\u00b0 increment)<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-even tr-4\">\n<td class=\"td-0\">Minimum measurable pupil diameter<\/td>\n<td class=\"td-1\">2.5 mm<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-odd tr-last\">\n<td class=\"td-0\">Fixationsziel<\/td>\n<td class=\"td-1\">hot air balloon over a landscape<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/en.oculus.de\/fileadmin\/images\/sonstiges\/trans_1px.jpg\" alt=\"\" \/><\/p>\n<table class=\"contenttable contenttable-0 technischeDaten\">\n<caption>Technische Spezifikationen<\/caption>\n<\/table>\n<table class=\"contenttable contenttable-0 technischeDaten\">\n<tbody>\n<tr class=\"tr-even tr-0\">\n<td class=\"td-0\">Dimensions (W x D x H)<\/td>\n<td class=\"td-1\">266 x 538 x 493 \u2013 523 mm<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-odd tr-1\">\n<td class=\"td-0\">Gewicht<\/td>\n<td class=\"td-1\">approx. 12 kg<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-even tr-2\">\n<td class=\"td-0\">Voltage<\/td>\n<td class=\"td-1\">80 &#8211; 264 V AC<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-odd tr-3\">\n<td class=\"td-0\">Frequency power supply unit<\/td>\n<td class=\"td-1\">47 &#8211; 63 Hz<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-even tr-4\">\n<td class=\"td-0\">Interface<\/td>\n<td class=\"td-1\">USB<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<tr class=\"tr-odd tr-last\">\n<td class=\"td-0\">Recommended computer specifications<\/td>\n<td class=\"td-1\">Intel\u00ae Core\u2122 i5, 500 GB HDD, 8 GB RAM, Windows\u00ae 10, Intel\u00ae HD Graphics<\/td>\n<td class=\"td-last td-2\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Referenzbibliothek<\/h2>\n<ul>\n<li><a href=\"https:\/\/en.oculus.de\/en\/products\/myopia-management\/myopia-master\/\" target=\"_blank\" rel=\"noopener nofollow\">Herstellerinformationen<\/a><\/li>\n<li><a href=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/08\/myopia_master_brochure_saturn_optical.pdf\">Brosch\u00fcre<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\"><strong>Oculus Myopia Master<\/strong> is the first all-in-one instrument that combines the essential things in 1 device. The built-in autorefractor obtains the objective refraction.<\/p>","protected":false},"featured_media":1917,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[239],"product_tag":[265],"class_list":["post-1912","product","type-product","status-publish","has-post-thumbnail","product_cat-myopia-and-dry-eye","product_tag-oculus-myopia-master","first","instock","sale","shipping-taxable","purchasable","product-type-simple","rey-swatches",""],"acf":[],"_links":{"self":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product\/1912","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/comments?post=1912"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/media\/1917"}],"wp:attachment":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/media?parent=1912"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product_cat?post=1912"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product_tag?post=1912"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}