{"id":2627,"date":"2025-06-12T14:45:25","date_gmt":"2025-06-12T14:45:25","guid":{"rendered":"https:\/\/saturnoptical.com\/?post_type=product&#038;p=2627"},"modified":"2025-06-12T14:52:08","modified_gmt":"2025-06-12T14:52:08","slug":"zeiss-iol-master-500-optical-biometer","status":"publish","type":"product","link":"https:\/\/saturnoptical.com\/de\/product\/zeiss-iol-master-500-optical-biometer\/","title":{"rendered":"Zeiss IOL Master 500 Optical Biometer"},"content":{"rendered":"<p>The IOLMaster 500 from ZEISS is the best choice for optical biometry. It has already performed over 100 million successful IOL power calculations.<\/p>\n<p>The ZEISS IOLMaster 500 is a great option for cataract surgeons. It is a reliable, fast, easy-to-use optical biometer, so surgeons can trust its measurements.<\/p>\n<p>The\u00a0<strong>ZEISS IOLMaster 500<\/strong> is a trusted biometry solution. Its design provides quick, accurate, and repeatable measurements. It helps make cataract surgery planning easier and improves vision results. With over 100 million IOL power calculations performed globally, it&#8217;s the proven choice for ophthalmic professionals.<\/p>\n<p><iframe title=\"\" src=\"https:\/\/www.youtube.com\/embed\/NkG7Qre_hXs\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><br \/>\nPowered by <a href=\"https:\/\/youtubeembedcode.com\" rel=\"nofollow noopener\" target=\"_blank\">youtube embed code<\/a> and <a href=\"https:\/\/beviljaralla.se\/\" rel=\"nofollow noopener\" target=\"_blank\">sms l\u00e5n som beviljar alla utan uc<\/a><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<h2>The new IOLMaster 500 features several advanced new capabilities, including:<\/h2>\n<ul>\n<li>Increased Speed: In practice studies, the new IOLMaster 500 can finish all measurements in just 80 seconds.<\/li>\n<li>Holladay 2 Calculations: The IOLMaster 500 includes this advanced fourth-generation formula, which is the top formula used by U.S. surgeons.<\/li>\n<li>Dual-mode measurements allow you to collect axial length and keratometry calculations simultaneously, at the push of a button.<\/li>\n<li>Composite Signal Filtering: This new sound filtering technology removes bad readings, helping more cataract patients be measured.<\/li>\n<li>Seamless Data Integration with the Synergy Ultrasound A-scan: This time-saving feature allows easy workflow integration of A-scan ultrasound biometry for difficult cases, such as extremely dense cataracts.<\/li>\n<li>New Graphical User Interface: With green, red and yellow \u201ctraffic light\u201d reporting, technicians of all experience levels will know when the optimum measurement position has been reached.<\/li>\n<\/ul>\n<div class=\"headline spacing--m hl-xl\">\n<h3><span class=\"headline__main\" data-js-select=\"Headline_main\">Refractive outcomes you can trust<\/span><\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-large wp-image-2926\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-1024x1024.jpg\" alt=\"iolmaster500-product-usage-01\" width=\"1024\" height=\"1024\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-1024x1024.jpg 1024w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-300x300.jpg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-150x150.jpg 150w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-768x768.jpg 768w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-800x800.jpg 800w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01-100x100.jpg 100w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster500-product-usage-01.jpg 1228w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<\/div>\n<div class=\"text text--body-m\">\n<p>The ZEISS IOLMaster is the only optical biometer to feature\u00a0<b>distance-independent telecentric keratometry<\/b>.<\/p>\n<p>It enables\u00a0<b>robust and repeatable\u00a0<\/b>measurements and shows excellent agreement with manual keratometry while achieving\u00a0<b>higher precision.<\/b><sup>1<\/sup>\u00a0In combination with a wide variety of established\u00a0<b>formulas<\/b>, you can achieve refractive outcomes you can trust.<sup>2<\/sup><\/p>\n<div class=\"headline spacing--m hl-xl\">\n<h3><span class=\"headline__main\" data-js-select=\"Headline_main\">Fast and easy to use<\/span><\/h3>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-2927\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_joystick.jpg\" alt=\"iolmaster_500_joystick\" width=\"746\" height=\"746\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_joystick.jpg 746w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_joystick-300x300.jpg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_joystick-150x150.jpg 150w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_joystick-100x100.jpg 100w\" sizes=\"(max-width: 746px) 100vw, 746px\" \/><\/p>\n<\/div>\n<div class=\"text text--body-m\">\n<p>A\u00a0<b>well-designed user interface<\/b>, plausibility checks, distance-independent measurements and a reading that\u2019s up to 4 times faster compared to other optical devices provide\u00a0<b>outstanding usability<\/b>\u00a0and reduced chair time.<sup>3<\/sup>\u00a0You can measure both eyes in\u00a0<b>less than 60 seconds<\/b><sup>4<\/sup>. A difference you, your team and your patients will notice every day.<\/p>\n<div class=\"headline spacing--m hl-xl\">\n<h3><span class=\"headline__main\" data-js-select=\"Headline_main\">Advanced measurement of challenging eyes<\/span><\/h3>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-2928\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_magnifying_glasses.jpg\" alt=\"iolmaster_500_magnifying_glasses\" width=\"666\" height=\"666\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_magnifying_glasses.jpg 666w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_magnifying_glasses-300x300.jpg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_magnifying_glasses-150x150.jpg 150w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmaster_500_magnifying_glasses-100x100.jpg 100w\" sizes=\"(max-width: 666px) 100vw, 666px\" \/><\/p>\n<\/div>\n<div class=\"text text--body-m\">\n<p>In denser cataracts the ZEISS IOLMaster 500 achieves a\u00a0<b>measurement success ratio<\/b>\u00a0that is up to\u00a0<b>20% higher<\/b>\u00a0than that of other optical biometers<sup>5<\/sup>, allowing a cataract penetration rate of more than 93%<sup>6<\/sup>. Even with staphyloma, pseudophakic and silicone-filled eyes, the ZEISS IOLMaster 500 measures along the visual axis. And with its Haigis-L formula, the ZEISS IOLMaster 500 allows IOL calculation for myopic and hyperopic post-LVC cases.<\/p>\n<div class=\"headline spacing--m hl-xl\">\n<h3><span class=\"headline__main\" data-js-select=\"Headline_main\">Precise and efficient markerless toric IOL alignment<sup>7, 8<\/sup><\/span><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-2929\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/zeiss-cataract-suite.jpg\" alt=\"zeiss-cataract-suite\" width=\"765\" height=\"765\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/zeiss-cataract-suite.jpg 765w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/zeiss-cataract-suite-300x300.jpg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/zeiss-cataract-suite-150x150.jpg 150w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/zeiss-cataract-suite-100x100.jpg 100w\" sizes=\"(max-width: 765px) 100vw, 765px\" \/><\/p>\n<\/div>\n<div class=\"text text--body-m\">\n<p>The ZEISS IOLMaster 500 is an integral part of the ZEISS Cataract Suite. A reference image is acquired and used for intraoperative matching with the live eye image during cataract surgery. Manual marking steps can be skipped altogether for\u00a0<b>efficient<\/b><sup>8<\/sup>\u00a0and more\u00a0<b>precise<\/b><sup>7<\/sup>\u00a0toric IOL alignment with\u00a0<b>reduced residual astigmatism.<\/b><sup>9<\/sup><\/p>\n<\/div>\n<div class=\"benefits__button\">\n<div class=\"button-link button-link--link\"><a class=\"button-link--icon button-link--internal\" title=\"Learn more about ZEISS Cataract Suite\" href=\"https:\/\/www.zeiss.com\/meditec\/en\/specialties\/ophthalmology.html#cataract\" target=\"_blank\" rel=\"noopener nofollow\" aria-label=\"Learn more about ZEISS Cataract Suite\" data-track-auto=\"true\" data-track-event=\"{&quot;name&quot;:&quot;CTA&quot;,&quot;type&quot;:&quot;Internal&quot;,&quot;action&quot;:&quot;Click&quot;,&quot;value&quot;:&quot;Learn more about ZEISS Cataract Suite&quot;,&quot;detail&quot;:&quot;https:\/\/www.zeiss.com\/meditec\/en\/specialties\/ophthalmology.html#cataract&quot;,&quot;moduleSection&quot;:&quot;benefits-1788742852&quot;,&quot;moduleType&quot;:&quot;Benefits&quot;}\"><span class=\"button-link__content\"><span class=\"button__text\">Learn more about ZEISS Cataract Suite. <\/span><\/span><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div class=\"module-headline spacing--l\">\n<div class=\"grid__structure\">\n<div class=\"grid__column module-headline--column\">\n<div class=\"headline hl-l headline--align-center hl--sub-xs\">\n<h2><span class=\"headline__main\" data-js-select=\"Headline_main\">Specifications<\/span><\/h2>\n<h3 class=\"headline__sub hl--sub\">ZEISS IOLMaster 500<\/h3>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"table\">\n<div class=\"table--multi-column table__wrapper table--expandable\" data-init-rows=\"4\" data-module=\"Table\">\n<table class=\"table__table\" data-js-select=\"Table_expandable-table\">\n<tbody>\n<tr data-js-select=\"Table_row\">\n<th class=\"table__first-col\" rowspan=\"4\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--center\">Measurement range<\/div>\n<\/th>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Axial length 14 \u2013 38 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Corneal radii 5 \u2013 10 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Anterior chamber depth 1.5 \u2013 6.5 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr class=\"table__init-row\" data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">White-to-white 8 \u2013 16 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<th class=\"table__first-col\" rowspan=\"4\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--center\">Display scaling<\/div>\n<\/th>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Axial length 0.01 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Corneal radii 0.01 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Anterior chamber depth 0.01 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">White-to-white 0.1 mm<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<th class=\"table__first-col\" rowspan=\"5\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--center\">IOL calculation formulas<\/div>\n<\/th>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">\n<p>Haigis, Hoffer<sup>\u00ae<\/sup>\u00a0Q, Holladay 1 and 2, SRK<sup>\u00ae<\/sup>\u00a0II, SRK<sup>\u00ae<\/sup>\u00a0\/ T<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Haigis-L IOL calculation for eyes following myopic \/ hyperopic LASIK \/ PRK \/ LASEK surgery<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Calculation of phakic anterior and posterior chamber implants<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Optimization of IOL constants<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<th class=\"table__first-col\" rowspan=\"7\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--center\">Interfaces<\/div>\n<\/th>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Ultrasound data link<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">\n<p>ZEISS eyecare data management system FORUM<sup>\u00ae<\/sup><\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">ZEISS computer-assisted cataract surgery system CALLISTO eye (via USB)<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Data interface for electronic medical record (EMR) \/ patient management systems (PMS)<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Data export to USB storage media<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Export database for Holladay IOL Consultant and HIC.SOAP Pro<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Ethernet port for network connection and network printer<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"table__first-col\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Line voltage<\/div>\n<\/div>\n<\/td>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">100 \u2013 240 V \u00b1 10 % (self sensing)<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"table__first-col\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Line frequency<\/div>\n<\/div>\n<\/td>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">50 \u2013 60 Hz<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"table__first-col\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Performance consumption<\/div>\n<\/div>\n<\/td>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">max. 75 VA<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr data-js-select=\"Table_row\">\n<td class=\"table__first-col\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--headline h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">Laser class<\/div>\n<\/div>\n<\/td>\n<td class=\"\" data-js-select=\"Table_col\">\n<div class=\"table__cell table__cell--text h-aligned--left v-aligned--top\">\n<div class=\"text text--body-m\">1<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>Reference<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.zeiss.com\/meditec\/en\/products\/optical-biometers\/iolmaster-500.html\" rel=\"nofollow noopener\" target=\"_blank\">Manufacturer Information<\/a><\/li>\n<li><a href=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2025\/06\/iolmasterbrochure.pdf\">Brochure<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The Zeiss IOL Master 500 Optical Biometer offers precise, non-contact eye measurements to ensure accurate intraocular lens calculations for cataract surgery, enhancing surgical outcomes and patient care.<\/p>","protected":false},"featured_media":2931,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[198],"product_tag":[329],"class_list":["post-2627","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-biometry","product_tag-iolmaster-500","first","instock","sale","shipping-taxable","purchasable","product-type-simple","rey-swatches",""],"acf":[],"_links":{"self":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product\/2627","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/comments?post=2627"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/media\/2931"}],"wp:attachment":[{"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/media?parent=2627"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product_cat?post=2627"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/saturnoptical.com\/de\/wp-json\/wp\/v2\/product_tag?post=2627"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}