{"id":1682,"date":"2022-06-10T09:57:22","date_gmt":"2022-06-10T09:57:22","guid":{"rendered":"https:\/\/saturnoptical.com\/?post_type=product&#038;p=1682"},"modified":"2022-08-16T07:59:17","modified_gmt":"2022-08-16T07:59:17","slug":"nidek-mp-3","status":"publish","type":"product","link":"https:\/\/saturnoptical.com\/fr\/product\/nidek-mp-3\/","title":{"rendered":"Nidek MP 3  Automatic Microperimeter with a Non-mydriatic Fundus Camera"},"content":{"rendered":"<p style=\"text-align: justify;\">Nidek MP 3 Microperimeter offers the possibility of specifically examining the still-existing function of morphologically conspicuous retinal areas. During microperimetry, the device&#8217;s automatic retina tracking ensures that the presented test stimuli are projected precisely onto the selected points of the patient&#8217;s retina. Continuous retina observation also ensures repeated testing on the same retinal site.<\/p>\n<p style=\"text-align: justify;\">The perimetry results are then overlaid with the images from the color fundus camera. The selective agreement of functional and morphological examinations creates the conditions for well-founded diagnoses and therapeutic decisions. The easy and uncomplicated operation of the Nidek MP 3 makes the examination with the microperimeter delegable. The data can be viewed stationary or transferred to a data network.<\/p>\n<p style=\"text-align: justify;\">\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<\/p>\n<div class=\"embed-container\" style=\"text-align: justify;\"><iframe src=\"https:\/\/www.youtube.com\/embed\/bgcK57hj65k\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<h2><\/h2>\n<p style=\"text-align: justify;\"><span style=\"color: inherit; font-family: inherit; font-size: var(--h2-font-size); font-weight: var(--font-weight-bold); text-align: justify; background-color: var(--body-bg-color);\">Nidek MP 3 Microperimeter Features:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"text-align: justify;\">Large measuring range (0 to 34 dB).<\/li>\n<li style=\"text-align: justify;\">Auto tracking and Auto alignment.<\/li>\n<li style=\"text-align: justify;\">Feedback research for visual rehabilitation.<\/li>\n<li style=\"text-align: justify;\">High-resolution nonmydriatic fundus camera.<\/li>\n<li style=\"text-align: justify;\">Scotopic microperimetry (option).<\/li>\n<li style=\"text-align: justify;\">Easy to combine with the Nidek RS-3000 Advance 2 OCT for better diagnostics.<\/li>\n<li style=\"text-align: justify;\">Microperimetry with a wide measurement range<\/li>\n<li style=\"text-align: justify;\">Fixation test with a precise tracking system<\/li>\n<li style=\"text-align: justify;\">High-resolution non-mydriatic fundus camera<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\">Easy Image Acquisition for Easy Follow-up.<\/h3>\n<p style=\"text-align: justify;\">Microperimetry, 12-megapixel color fundus image, fixation analysis, and visual rehabilitation; The 12-megapixel fundus camera in the MP-3 acquires high-resolution retinal pathology images.<\/p>\n<p style=\"text-align: justify;\">Nidek MP 3 is the new microperimeter developed by Nidek, which replaces and innovates the previous model MP-1, the first product in the world to propose this technology.<\/p>\n<p style=\"text-align: justify;\">Microperimetry is a subjective, non-invasive diagnostic test used to determine the retinal function and provides important information to complete morphological tests.<\/p>\n<p style=\"text-align: justify;\">Nidek MP 3 is a tool that integrates the two analyses, functional and morphological, and allows a precise correlation between the two.<\/p>\n<h3 style=\"text-align: justify;\"><strong>More Features details:<\/strong><\/h3>\n<div class=\"acms-col-6 comModSecNormal\" style=\"text-align: justify;\">\n<ul>\n<li class=\"column-image-auto\">The Nidek MP 3 has a wider range of stimulus intensity, from 0 to 34 dB, compared to the MP-1. The MP-3 measures perimetric threshold values, even for normal eyes. A maximum stimulus luminance of 10,000 asb* allows evaluation of low sensitivity.<\/li>\n<li class=\"column-image-auto\">Auto tracking and auto-alignment functions provide more accurate measurements increasing patient and operator comfort and efficiency. These functions allow easy follow-up and reduce variations between examiners, resulting in well-aligned follow-up exams.<\/li>\n<li class=\"column-image-auto\">The MP-3 can measure fixation and determine the preferred retinal locus simply by having the patient fixate on a target. Any change in fixation can be compared pre- and post-treatment because the patient\u2019s eye is constantly tracked during microperimetry. This test evaluates fixation in patients with central visual field defects and determines whether fixation improved after treatment.<\/li>\n<li class=\"column-image-auto\">The 12-megapixel fundus camera in the MP-3 acquires high-resolution retinal pathology images and allows easy image acquisition.<\/li>\n<li class=\"column-image-auto\">Various OCT modalities captured by NIDEK RS-3000 Advance can be registered with microperimetry.<\/li>\n<\/ul>\n<h3 id=\"h115137\">Microperimetry<\/h3>\n<h4 id=\"h115169\">Wide measurement range<\/h4>\n<hr class=\"clearHidden\" \/>\n<p>The Nidek MP 3 has a wider range of stimulus intensity, from 0 to 34 dB, compared to the MP-1. The MP-3 measures perimetric threshold values, even for normal eyes. A maximum stimulus luminance of 10,000 asb* allows evaluation of low sensitivity.<\/p>\n<p>*By ISO12866 measurement methods<\/p>\n<div class=\"acms-col-6 comModSecNormal\">\n<hr class=\"clearHidden\" \/>\n<div class=\"column-image-center\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium wp-image-1687\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/MP-3-Normal-Eye-Image-300x221.jpeg\" alt=\"\" width=\"300\" height=\"221\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/MP-3-Normal-Eye-Image-300x221.jpeg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/MP-3-Normal-Eye-Image.jpeg 725w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"caption\">MP-3 Normal Eye Image(34dB)<\/p>\n<\/div>\n<\/div>\n<div class=\"acms-col-6 comModSecNormal\">\n<hr class=\"clearHidden\" \/>\n<div class=\"column-image-center\">\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-1686\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/MP-3-Glaucomatous-Eye-Image-300x221.jpeg\" alt=\"\" width=\"300\" height=\"221\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/MP-3-Glaucomatous-Eye-Image-300x221.jpeg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/MP-3-Glaucomatous-Eye-Image.jpeg 725w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"caption\">MP-3 Glaucomatous Eye Image(34dB)<\/p>\n<\/div>\n<\/div>\n<hr class=\"clearHidden\" \/>\n<\/div>\n<section class=\"sModSecNormal sUnitArea\">\n<h3 id=\"h115166\">Fixation test<\/h3>\n<hr class=\"clearHidden\" \/>\n<h4 id=\"h115167\">Precise tracking system<\/h4>\n<p>The Nidek MP 3 can measure fixation and determine the preferred retinal locus simply by having the patient fixate on a target Constant tracking of the eye during microperimetry allows evaluation of fixation in patients with central visual field defects and determines whether fixation improves after treatment.<\/p>\n<div class=\"acms-col-6 comModSecNormal\">\n<hr class=\"clearHidden\" \/>\n<div class=\"column-image-center\">\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-1688\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Stable-Fixation-300x198.jpeg\" alt=\"\" width=\"300\" height=\"198\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Stable-Fixation-300x198.jpeg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Stable-Fixation.jpeg 725w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"caption\">Stable Fixation<\/p>\n<\/div>\n<\/div>\n<div class=\"acms-col-6 comModSecNormal\">\n<hr class=\"clearHidden\" \/>\n<div class=\"column-image-center\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1689\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Unstable-Fixation-300x201.jpeg\" alt=\"\" width=\"300\" height=\"201\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Unstable-Fixation-300x201.jpeg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Unstable-Fixation.jpeg 723w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"caption\">Unstable Fixation<\/p>\n<\/div>\n<\/div>\n<hr class=\"clearHidden\" \/>\n<h3 id=\"h115154\">Retinography<\/h3>\n<hr class=\"clearHidden\" \/>\n<h4 id=\"h115155\">High-resolution non-mydriatic fundus camera<\/h4>\n<div class=\"acms-col-8 comModSecNormal\">\n<hr class=\"clearHidden\" \/>\n<p>An easy-to-use 12-megapixel fundus camera is incorporated into the Nidek MP 3, acquiring high-resolution retinal pathology images.<\/p>\n<\/div>\n<div class=\"acms-col-4 comModSecNormal\">\n<hr class=\"clearHidden\" \/>\n<div class=\"column-image-auto\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1690\" src=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Fundus-Camera-Image-300x300.jpeg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Fundus-Camera-Image-300x300.jpeg 300w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Fundus-Camera-Image-150x150.jpeg 150w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Fundus-Camera-Image-100x100.jpeg 100w, https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/Fundus-Camera-Image.jpeg 504w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"caption\">Fundus Camera Image<\/p>\n<\/div>\n<\/div>\n<\/section>\n<h3 style=\"text-align: justify;\">Nidek MP-3 Specifications<\/h3>\n<div>\n<ul style=\"text-align: justify;\">\n<li style=\"text-align: justify;\"><strong>Device<\/strong><br \/>\nMicroperimeter<\/li>\n<li style=\"text-align: justify;\"><strong>Model<\/strong><br \/>\nMP-3 &amp; MP-3 type S<\/li>\n<li style=\"text-align: justify;\"><strong>Type<\/strong><br \/>\nDiagnostic<\/li>\n<li style=\"text-align: justify;\"><strong>Specialty<\/strong><br \/>\nRetina &amp; Glaucoma<\/li>\n<li style=\"text-align: justify;\"><strong>Performance<\/strong><br \/>\n40\u00ba Angle of View for Microperimetry &amp; 45\u00ba Angle of View for Fundus Camera<\/li>\n<li style=\"text-align: justify;\"><strong>Technology<\/strong><br \/>\n3D Auto Tracking &amp; Auto Shot<\/li>\n<li style=\"text-align: justify;\"><strong>Design<\/strong><br \/>\n10.4&#8243; Color LCD Touch Screen<\/li>\n<li style=\"text-align: justify;\"><strong>Dimensions &amp; Weight<\/strong><br \/>\n13.1 in W x 22.1 in D x 22.0 in H<\/li>\n<li style=\"text-align: justify;\"><strong>Accessories<\/strong><br \/>\nNAVIS-EX software<\/li>\n<\/ul>\n<h3 style=\"text-align: justify;\">What&#8217;s Included<\/h3>\n<ul style=\"text-align: justify;\">\n<li>Limited Service Warranty<\/li>\n<li>Complimentary Support<\/li>\n<li>On-Site &amp; Remote Assistance<\/li>\n<li>Access to Learning Resources<\/li>\n<\/ul>\n<h2 style=\"text-align: justify;\">Reference Library<\/h2>\n<ul>\n<li style=\"text-align: justify;\"><a href=\"https:\/\/www.nidek-intl.com\/product\/ophthaloptom\/diagnostic\/dia_retina\/mp-3.html\" target=\"_blank\" rel=\"noopener nofollow\">Manufacturer Information<\/a><\/li>\n<li style=\"text-align: justify;\"><a href=\"https:\/\/saturnoptical.com\/wp-content\/uploads\/2022\/06\/nidek_mp_3_brochure_Saturn_optical_com.pdf\">Brochure<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\">Nidek MP-3 Microperimeter offers the possibility of explicitly examining the still-existing function of morphologically conspicuous retinal areas.<\/p>","protected":false},"featured_media":1683,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_cat":[185],"product_tag":[233],"class_list":["post-1682","product","type-product","status-publish","has-post-thumbnail","product_cat-perimeters","product_tag-nidek-mp-3","pa_brand-nidek","first","instock","sale","shipping-taxable","purchasable","product-type-simple","rey-swatches",""],"acf":[],"_links":{"self":[{"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/product\/1682","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/comments?post=1682"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/media\/1683"}],"wp:attachment":[{"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/media?parent=1682"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1682"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/saturnoptical.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1682"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}