Optopol PTS 925W Automated Perimeter
Original price was: $6,999.00.$3,999.00Current price is: $3,999.00.-43% OFF
The Optopol PTS 925W Automated Perimeter provides precise and efficient visual field testing, featuring user-friendly operation and advanced analysis tools. Ideal for glaucoma and neurological assessments, this perimeter ensures accurate diagnostics and enhanced patient care. Available now at Saturn Optical.
In stock
Description
The Optopol PTS 925W brings the world’s most popular visual field patterns 30-2 and 24-2 into a compact device.
Despite its compact size, the 925W offers cutting-edge design and software capabilities. With a 170° horizontal and 110° vertical testing range, the PTS 925W is more than capable of managing diseases. From precise macula thresholding to the binocular Esterman driving test — everything is within reach.
The Optopol PTS 925W automated perimeter provides everything you need in a compact footprint. The PTS automated perimeter series are modern diagnostic instruments for precise and fast testing of visual fields. They use standard perimetry testing methods.
UNIQUE FEATURES:
- Windows 10 Operating System for ease-of-use and support
- DICOM and EMR and wireless printing capability – standard
- All PTS perimeters have peripheral testing capability
- Blue LED band around the unit to provide ambient light to the operator and patient
- Optional data transfer for your existing HFA perimeter
- Comprehensive 2 – year warranty on all units sold for a limited time
The PTS 925W automated perimeter is a modern diagnostic instrument for precise and fast testing of visual fields. In addition to standard perimetry tests, they use the latest visual field testing methods. This saves time and provides high precision and reliability. Intuitive software, combined with powerful networking and EMR integration, and maintenance-free, reliable hardware, creates the best tools for visual field testing.

ALL THAT YOU NEED
- Complete set of standard perimetry tests.
- Variety of threshold algorithms and screening techniques.
- Binocular Driver’s Test, Flicker perimetry.
- Complete palette of analysis tools for quick and thorough assessment of visual fields.
- Comparison and progression module available in standard package.
- Standard test reports and global indices.
- White on white testing
- Goldmann standard bowl
- 170° horizontal and 110° vertical testing range
- 30-2 , 24-2 and 10-2 testing fields.
THRESHOLD IN 3 MINUTES*
- ZETA™ Fast Threshold strategy – quicker examination without loss in result resolution.
- 24-2 field tested in less than 3 minutes (30-2 in less than 4 minutes)*.
- Provides more detailed information than screening strategies in comparable duration.
SUPREME RELIABILITY
- High resolution camera for precise monitoring of patients’ compliance.
- Blink control – no stimuli are omitted due to normal blinking, test is put on hold until the eye is opened again.
- Eye tracking – analyses pupil movement and assures supreme reliability of test results.
- Voice messages assist operator and patient during the examination.
FLEXIBILITY FOR TIME
- Rich library of predefined test fields and programs.
- Custom test settings can be stored and accessed with a single touch.
- Follow-up tests can be performed by simply selecting the base examination.
- Partial test results of not completed test can be continued at a later date.
DICOM, GDT, EMR, NETWORK INTEGRATION
- Built-in networking features – data can be accessed from anywhere within your network.
- Out of the box DICOM support.
- Storing visual field reports on the DICOM image server.
- DICOM Modality Worklist support.
- GDT interface and custom EMR’s based on text file interface.
Technical Specifications
| Examination bowl | 300 mm radius, spherical, closed type, ventilated |
| Tested field range | Superior – 40° Inferior – 40° (55° with fixation shift) Left to right – 100° (170° with fixation shift) |
| Testing techniques | Static perimetry |
| Stimulus sizes (Goldmann) | III |
| Stimulus colors | White |
| Background illumination | White 10 cd/m2 (31.5 asb) |
| Maximum stimulus intensity | 10,000 asb |
| Fixation control | Gaze tracking Blink monitoring Heijl/Krakau V-Eye™ (Virtual Identification of Eye Position) |
| Chinrest control | Electrical up-down |
| Patient response time | Set manually 0.1 to 9.9 s Adaptive to patient speed |
| Test fields | Test field patterns 10-2, 24-2, 30-2 |
| Test strategies | Screening (Quantify defect, 3-zone, 2-zone) Threshold (Threshold, Fast Threshold, Advanced Threshold) Special (BSV, Flicker) Esterman Test |
| Analysis | Single field analysis Result comparison Defect progression Statistical package |
| Connectivity | DICOM Storage SCU DICOM MWL SCU GDT, TXT, CMDL Networking |
| Device interface | USB 2.0 |
| Dimensions inches (HxWxD) | 16 x 22 x 16 , 19 lbs |
| Operating Voltage | 100-120 V AC 50-60 Hz or 220-240 V AC 50-60 Hz |
| Power consumption | 30 W |
Includes: New Laptop and Table.