Kowa AP-7000 Automatic Perimeter Visual Field
Original price was: $6,666.00.$2,222.00Current price is: $2,222.00.-67% OFF
Discover the Kowa AP-7000 with our comprehensive guide. Learn about its benefits, expert tips, and how to maximize its potential in your clinic. Perfect for optometrists and ophthalmologists.
In stock
Description
The Kowa AP-7000 is a cutting-edge visual field analyzer designed to meet the demands of modern optometry and ophthalmology practices. Known for its high diagnostic accuracy, user-friendly interface, and advanced features, the Kowa AP-7000 is an indispensable tool for eye care professionals aiming to provide top-notch patient care. This device offers comprehensive visual field testing, ensuring early detection and management of various eye conditions, including glaucoma.
Accurate and efficient visual field testing is crucial for detecting and managing eye diseases that can lead to vision loss. Glaucoma, retinal disorders, and optic nerve damage can be effectively monitored and treated if diagnosed early through reliable visual field analysis. The Kowa AP-7000 ensures high precision and speed, reducing the burden on patients and practitioners and enhancing the overall quality of eye care.
Kowa AP-7000 Key Features and Benefits
- High Diagnostic Accuracy: Enhanced algorithms for precise detection of visual field defects.
- User-Friendly Interface: Intuitive touch screen for easy operation.
- Fast Testing: Reduced test times with quick, reliable results.
- Patient Comfort: Ergonomic design to ensure a comfortable testing experience.
- EHR Integration: Seamless compatibility with major electronic health record systems.
- Durable Construction: Built to withstand the rigors of daily clinical use.
Fundus Oriented Perimetry
Static perimetry tests can be applied to areas of interest on fundus images taken from a retinal camera, OCT, or SLO. Threshold test within the central 10°, custom optional threshold test that allows selection of any desired test points, and custom optional screening tests are available.
Threshold
In addition to central 30° used to observe the progression of glaucoma, other tests are available such as central 10° which can identify visual field abnormalities in the macula.
Clear Display of Analysis Results
Analysis Indices
For this index, threshold central test points are divided into 10 sectors, and corresponding sectors above and below the axis of the horizontal median are compared.
VFI (Visual Field Index)
A percentage index in which a normal visual field is 100% , and total loss of visual field is 0%
Anderson’s Criteria Diagnostic Support Function
This criteria is for glaucomatous visual field defect.
If any of the following conditions are satisfied, the colors turn orange.
- PSD has p<5%
- GHT is outside normal limits
- Pattern deviation probability plot shows a cluster of 3 or more nonedge points that have p<5%, and one of the points has p<1% (The physician must judge whether the 3 points match the travel of NFL.)
Chronological Change Display
Test result analysis indices can be graphically displayed as time series data to give a clear grasp of changes over time in the tested eyes.
Predictive Display
Predictive graphs are displayed from calculations of linear rates of changes in analysis indices. This function predicts what values of MD and VFI will be reached at what age, if current rates of change in those values continue.
Convenient Tabbed User Interface
Main operation buttons are grouped at the top of the page, and buttons are laid out to follow the progression of tests, from patient information entry through test program selection to result display.
Screening
4-zone measurement that goes beyond screening, and programs using probability values (p-values), are among the features that enable effective testing in less time.
Running tests with probability value (p-value) intensities makes it possible to display the difference between the measured value and the normal value for each age range as a p-value, so that the evaluation equivalent to total deviation in thresholds can be performed in a shorter time.
Isopter
“Automatic measurement function”, using many median patterns, “Manual measurement function”, allowing free drawing of isopters, and “auto + manual measurement function”, which allows any drawing of median after automatic measurement, are among the diverse measurement method options available.
Software Capabilites
Why Clinics and Optometrists Must Use the Kowa AP-7000
The Kowa AP-7000 revolutionizes visual field testing by combining cutting-edge technology with ease of use, ensuring that clinics can offer the highest standard of patient care. Optometrists benefit from its fast and accurate diagnostics, allowing for early detection and management of conditions like glaucoma. Its robust integration capabilities with EHR systems streamline data management, enhancing overall clinic efficiency.
By investing in the Kowa AP-7000, eye care professionals can significantly improve diagnostic accuracy, patient satisfaction, and clinic productivity.
The purpose of this guide is to provide a detailed and comprehensive overview of the Kowa AP-7000, its benefits, and best practices for its use. Whether you are an optometrist, ophthalmologist, or clinic manager, this guide will offer valuable insights into maximizing the potential of the Kowa AP-7000 in your practice. From understanding its key features to learning expert tips and overcoming common challenges, this guide aims to enhance your proficiency and confidence in using this advanced visual field analyzer.
Top 5 Facts, Statistics, and Trends Related to Kowa AP-7000
- High Diagnostic Accuracy: The Kowa AP-7000 has been shown to improve diagnostic accuracy by 20% compared to older models, significantly aiding in the early detection of glaucoma and other visual field defects.
- Source: Journal of Clinical Ophthalmology
- Patient Satisfaction: Over 85% of patients reported a more comfortable and quicker testing experience with the Kowa AP-7000.
- Source: Patient Experience Survey, 2023
- Increased Efficiency: Clinics using the Kowa AP-7000 have reported a 30% increase in patient throughput due to the device’s fast and reliable performance.
- Source: Optometry Practice Efficiency Report, 2022
- Integration Capabilities: The Kowa AP-7000 is compatible with over 90% of EHR systems used in the United States, facilitating seamless data transfer and storage.
- Source: EHR Integration Study, 2021
- Market Trend: The adoption rate of advanced visual field analyzers like the Kowa AP-7000 is expected to grow by 15% annually, driven by the increasing prevalence of eye diseases.
- Source: Global Ophthalmic Device Market Report, 2023
Specifications
Stimulus presentation method | Projection |
Stimulus colour | White, red, blue, green |
Stimulus size | Goldmann I, II, III, IV, V |
Maximum stimulus intensity | 3,183cd/m2 (10,000 asb): white |
Stimulus presentation time | 0.2 sec |
Stimulus presentation interval | 0.6 ~3.3 sec. (automatically adjusted) |
Background intensity
*Automatic light adjustment |
White: 10cd/m2 (31.5asb)
Yellow: 100 cd/m2Â (314.2 asb) |
Examination distance | 300mm |
Measurements range | 80° |
External interface | USB, Ethernet |
Fixation Target | Orange LED,
Centre 1 point, auxiliary 4 point, fovea |
Eye fixation monitoring | Heijl-Krakau method, eye fixation monitor, gaze monitor |
Printout | USB-connected printer (available separately) |
Operation screen | Touch panel colour LCD monitor |
Data save | Built-in flash memory |
Operation support | Oral instruction |
Chin rest operation | Motor-driven |
Power supply | AC 100-230 V 50/60Hz
Power consumption: 200 VA |
Dimensions | 730(W) x 430(D) x 700(H) mm |
Weight | 26kg |
Examination
Screening | Program | Standard, Precision, Centre, Periphery, Glaucoma, V.Meridian, Centre #1, Centre # |
Method | 2zone, 3zone, 4zone, Quantify scotcoma
Intensity step : 5dB / probability variable (p-value) Quick mode is available |
|
Supra | Program | Standard, Macula, Mariotte, Optional, D-Test |
Method | Same intensity 2 zone | |
Threshold | Program | Centre1, Centre 2, Meridian, Macula 1, Macula 2, Periphery |
Method | All Threshold Quick 1, Quick 2, Super quick | |
Isopter | Program | Standard, Isopter + Screening 1, Isopter +Screening 2, Isopter + Threshold |
Method | Auto, manual | |
Custom | Program | Circle Threshold, 1 point threshold, Quadrant Threshold, Optional Threshold#,
Optional thresholdo, Screening#, Screeningo |
Perimetry on Fundus | Perimetry combined fundus image | |
Fovea examination | It is available in the Threshold Centre examination
(Threshold – Centre 1, Centre 2, Isopter + Threshold) |
FAQs about the Kowa AP-7000
What is the Kowa AP-7000?
The Kowa AP-7000 is an advanced visual field analyzer designed for optometrists and ophthalmologists to conduct precise and efficient visual field tests. It is known for its high diagnostic accuracy, user-friendly interface, and compatibility with electronic health record systems.
How does the Kowa AP-7000 improve diagnostic accuracy?
The Kowa AP-7000 improves diagnostic accuracy through its advanced algorithms and state-of-the-art technology, which ensure precise detection of visual field defects. This accuracy is crucial for early diagnosis and effective management of conditions such as glaucoma and optic nerve damage.
What are the maintenance requirements for the Kowa AP-7000?
The Kowa AP-7000 requires regular maintenance to ensure optimal performance. This includes routine calibration, cleaning of the device, and software updates. Following the manufacturer’s maintenance guidelines helps in maintaining the device’s accuracy and extending its lifespan.
Can the Kowa AP-7000 integrate with my clinic’s EHR system?
Yes, the Kowa AP-7000 is designed to integrate seamlessly with most electronic health record (EHR) systems used in the United States. This compatibility facilitates easy data transfer, storage, and retrieval, improving overall workflow efficiency in clinical settings.
How long does a typical visual field test take with the Kowa AP-7000?
A typical visual field test with the Kowa AP-7000 is quick and efficient, usually taking around 5 to 10 minutes per eye. The exact duration may vary depending on the specific test protocol used and the patient’s condition.
Conclusion
The Kowa AP-7000 is a state-of-the-art visual field analyzer that offers numerous benefits, including enhanced patient experience, improved diagnostic accuracy, time efficiency, and reliability. Its compatibility with EHR systems further streamlines clinical workflows, making it an invaluable tool for eye care professionals.
Encouragement to Invest in the Kowa AP-7000 for Improved Patient Care
Investing in the Kowa AP-7000 means investing in the future of your practice and the health of your patients. Its advanced features and reliability ensure that you can provide the highest standard of care, leading to better patient outcomes and increased satisfaction.
To learn more about the Kowa AP-7000 and how it can enhance your practice, visit our website or contact our sales team. Take the first step towards improving your clinic’s diagnostic capabilities and patient care by investing in the Kowa AP-7000 today.
Reference
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.